© RGS Engineering Solutions Ltd 2017
BLASFORMTECHNIK
HESTA Blasformtechnik GmbH & Co. KG Jahnstraße 84, D - 7 3 0 3 7  Göppingen, Tel: +49 (0) 7161 / 504 67-0, Fax: +49 (0) 7161 / 504 67- 2 9 www.hesta.de, info @ hesta.de
Modification reserved Standard voltage: 3 x 380V, 50 Hz Alternative centre distances possible Please ask for additional equipment The effective consumption data for Energy- and cooling requirements are product dependent. The Air requirement is an approximate value, it can change according to produced article.
• • • We reserve the right to change technical specifications without prior notice.
H E S T A 3 1 0   E    H E S T A 3 6 0   E
Double station blow moulder with horizontal linear mould shuttle / all-electric driven-Version Width:        2474mm    (max.     2640mm)    Length:   2500mm   (max.   2500mm) Depth:  3710mm (max. 3350mm  )
Key Data HESTA 310 E HESTA 360 E mm mm Linear mould Stroke A 310  360 Mould Width B 300  350 Mould Length  C 340 340 Mould Thickness  D 2x90 ± 3mm 2x90 ± 3mm Opening Stroke E 155 155  Platen daylight 335 335  Clamping Force 60 kN 60 kN  Dry Cycle 1,4 sec. 1,6 sec. Centre Distances  2x2 fold 100/110/(125) 100/110/125/140 2x3 fold 70/85 70/85/100 2x4 fold 50/60 50/60/70  2x5 fold 50 50/60  2x6 fold 50 Extruder ø 50 ø 55 ø 60 ø 70  Drive Electromotor, infinitely variable Screw Speed min ¯ ¹ 0  85 0  85 0  80 0  80  Screw mm 50/22 D 55/22 D 60/22 D 70/22 D Energy Requirements Electrical Drives for 40kN  kW  11 11 11 11 Electromotor Extruder  kW  17  19 27 30 Heating Capacity Extruder  kW  12  14 17 24 Electric Control, approx.  kW 2 2 2 2 Total Connected Load, approx.   kW 42 46 57 67 Air Requirement, approx. Nl/min  1000/1200 1000/1200 1000/1200 1000/1200  Air Working Pressure bar 7-10 7-10 7-10 7-10 Cooling Requirement Extruder  kJ / h  8.000  8.000 12.000 12.000 Blow Mold  kJ / h 22.000 26.000 30.000 38.000
© RGS Engineering Solutions Ltd, 2017
HESTA Blasformtechnik GmbH & Co. KG Jahnstraße 84, D - 7 3 0 3 7  Göppingen, Tel: +49 (0) 7161 / 504 67-0, Fax: +49 (0) 7161 / 504 67- 2 9 www.hesta.de, info @ hesta.de
Modification reserved Standard voltage: 3 x 380V, 50 Hz Alternative centre distances possible Please ask for additional equipment The effective consumption data for Energy- and cooling requirements are product dependent. The Air requirement is an approximate value, it can change according to produced article.
• • • We reserve the right to change technical specifications without prior notice.
H E S T A 3 1 0   E    H E S T A 3 6 0   E
Double station blow moulder with horizontal linear mould shuttle / all-electric driven-Version Width:        2474mm    (max.     2640mm)    Length:   2500mm   (max.   2500mm) Depth:  3710mm (max. 3350mm)
Key Data HESTA 310 E HESTA 360 E mm mm Linear mould Stroke A 310  360 Mould Width B 300  350 Mould Length  C 340 340 Mould Thickness  D 2x90 ± 3mm 2x90 ± 3mm Opening Stroke E 155 155  Platen daylight 335 335  Clamping Force 60 kN 60 kN  Dry Cycle 1,4 sec. 1,6 sec. Centre Distances  2x2 fold 100/110/(125) 100/110/125/140 2x3 fold 70/85 70/85/100 2x4 fold 50/60 50/60/70  2x5 fold 50 50/60  2x6 fold 50 Extruder ø 50 ø 55 ø 60 ø 70  Drive Electromotor, infinitely variable Screw Speed min ¯ ¹ 0  85 0  85 0  80 0  80  Screw mm 50/22 D 55/22 D 60/22 D 70/22 D Energy Requirements Electrical Drives for 40kN  kW  11 11 11 11 Electromotor Extruder  kW  17  19 27 30 Heating Capacity Extruder  kW  12  14 17 24 Electric Control, approx.  kW 2 2 2 2 Total Connected Load, approx.   kW 42 46 57 67 Air Requirement, approx. Nl/min  1000/1200 1000/1200 1000/1200 1000/1200  Air Working Pressure bar 7-10 7-10 7-10 7-10 Cooling Requirement Extruder  kJ / h  8.000  8.000 12.000 12.000 Blow Mold  kJ / h 22.000 26.000 30.000 38.000