© RGS Engineering Solutions Ltd 2017
BLASFORMTECHNIK
HESTA Blasformtechnik GmbH & Co. KG Jahnstraße 84, D - 7 3 0 3 7  Göppingen, Tel: +49 (0) 7161 / 504 67-0, Fax: +49 (0) 7161 / 504 67- 2 9 www.hesta.de, info @ hesta.de
Modification reserved Standard voltage: 3 x 380V, 50 Hz Alternative centre distances possible Please ask for additional equipment The effective consumption data for Energy- and cooling requirements are product dependent. The Air requirement is an approximate value, it can change according to produced article.
• • • We reserve the right to change technical specifications without prior notice.
H E S T A 1 8 0   E   H E S T A 2 0 0   E
Single station blow moulder with horizontal linear mould shuttle and vertical extruder / all-electrical driven-Version Width:     1081mm Length:   2920mm Depth:      2386mm
Key Data HESTA 180E HESTA 200E mm  mm Linear mould Stroke A 180  200 Mould Width B 200  220 Mould Length  C 230  230 Mould Thickness  D 2x75 ± 3mm 2x75 ± 3mm Opening Stroke E 110 110  Platen daylight 260 260  Clamping Force 27 kN 27 kN  Dry Cycle 1,3 sec. 1,3 sec. Centre Distances  2 fold 50 /60/70 50 /60/70/85 3 fold 50 50 /60 4 fold available on request  Extruder ø 36 ø 45  Drive Electromotor, infinitely variable Screw Speed min ¯ ¹ 0  100 0  100  Screw mm 36 / 20 D 45 / 20 D Energy Requirements Electromotor Extruder  kW 6 11 Electrical Drives for 27kN  kW  4,2  4,2 Heating Capacity Extruder  kW  4,4  6,6 Electric Control, approx.  kW 1 1 Total Connected Load, approx.  kW 15,6 23,0 Air Requirement, approx. Nl / min 250 250 Air Working Pressure bar 7 - 10 7 - 10 Cooling Requirement Extruder System  kJ / h 6.000 6.000 Blow Mold  kJ / h 10.000 15.000
© RGS Engineering Solutions Ltd, 2017
HESTA Blasformtechnik GmbH & Co. KG Jahnstraße 84, D - 7 3 0 3 7  Göppingen, Tel: +49 (0) 7161 / 504 67-0, Fax: +49 (0) 7161 / 504 67- 2 9 www.hesta.de, info @ hesta.de
Modification reserved Standard voltage: 3 x 380V, 50 Hz Alternative centre distances possible Please ask for additional equipment The effective consumption data for Energy- and cooling requirements are product dependent. The Air requirement is an approximate value, it can change according to produced article.
• • • We reserve the right to change technical specifications without prior notice.
H E S T A 1 8 0   E   H E S T A 2 0 0   E
Single station blow moulder with horizontal linear mould shuttle and vertical extruder / all-electrical driven-Version Width:     1081mm Length:   2920mm Depth:      2386mm
Key Data HESTA 180E HESTA 200E mm  mm Linear mould Stroke A 180  200 Mould Width B 200  220 Mould Length  C 230  230 Mould Thickness  D 2x75 ± 3mm 2x75 ± 3mm Opening Stroke E 110 110  Platen daylight 260 260  Clamping Force 27 kN 27 kN  Dry Cycle 1,3 sec. 1,3 sec. Centre Distances  2 fold 50 /60/70 50 /60/70/85 3 fold 50 50 /60 4 fold available on request  Extruder ø 36 ø 45  Drive Electromotor, infinitely variable Screw Speed min ¯ ¹ 0  100 0  100  Screw mm 36 / 20 D 45 / 20 D Energy Requirements Electromotor Extruder  kW 6 11 Electrical Drives for 27kN  kW  4,2  4,2 Heating Capacity Extruder  kW  4,4  6,6 Electric Control, approx.  kW 1 1 Total Connected Load, approx.  kW 15,6 23,0 Air Requirement, approx. Nl / min 250 250 Air Working Pressure bar 7 - 10 7 - 10 Cooling Requirement Extruder System  kJ / h 6.000 6.000 Blow Mold  kJ / h 10.000 15.000