© RGS Engineering Solutions Ltd 2017
BLASFORMTECHNIK
HESTA Blasformtechnik GmbH & Co. KG Jahnstraße 84, D - 7 3 0 3 7  Göppingen, Tel: +49 (0) 7161 / 504 67-0, Fax: +49 (0) 7161 / 504 67- 2 9 www.hesta.de, info @ hesta.de
Modification reserved Standard voltage: 3 x 380V, 50 Hz Alternative centre distances possible Please ask for additional equipment The effective consumption data for Energy- and cooling requirements are product dependent. The Air requirement is an approximate value, it can change according to produced article.
• • • We reserve the right to change technical specifications without prior notice.
H E S T A 1 8 0    H E S T A 2 0 0
Single station blow moulder with horizontal linear mould shuttle and vertical extruder Width:     1081mm Length:   2700mm Depth:      2386mm
Key Data HESTA180 HESTA200 mm  mm Linear mould Stroke A 180  200 Mould Width B 200  220 Mould Length  C 230 (260) 230 (260) Mould Thickness  D 2x60 - 2x75 2x60-2x75 Opening Stroke E 140  - 110 140 - 110  Platen daylight 260 260  Clamping Force 27 kN 27 kN  Dry Cycle 1,3 sec. 1,3 sec. Centre Distances  2 fold 50 /60/70 50 /60/70/85 3 fold 50 50 /60 4 fold available on request  Extruder ø 36 ø 45  Drive Hydromotor, infinitely variable Screw Speed min ¯ ¹ 0  100 0  100  Screw mm 36 / 20 D 45 / 20 D
Energy Requirements Electromotor Hydraulic / Extruder
kW 7,5 11 
Heating Capacity (Extruder)
kW 4,4 6,6
Electric Control, approx.  kW 1 1 Total Connected Load, approx.  kW 13 19 Air Requirement, approx. Nl / min 250 250 Air Working Pressure bar 7 - 10 7 - 10 Cooling Requirement Hydraulic System  kJ / h 8.000  10.000 Blow Mold  kJ / h 10.000  15.000
© RGS Engineering Solutions Ltd, 2017
HESTA Blasformtechnik GmbH & Co. KG Jahnstraße 84, D - 7 3 0 3 7  Göppingen, Tel: +49 (0) 7161 / 504 67-0, Fax: +49 (0) 7161 / 504 67- 2 9 www.hesta.de, info @ hesta.de
Modification reserved Standard voltage: 3 x 380V, 50 Hz Alternative centre distances possible Please ask for additional equipment The effective consumption data for Energy- and cooling requirements are product dependent. The Air requirement is an approximate value, it can change according to produced article.
• • • We reserve the right to change technical specifications without prior notice.
H E S T A 1 8 0    H E S T A 2 0 0
Single station blow moulder with horizontal linear mould shuttle and vertical extruder Width:     1081mm Length:   2700mm Depth:      2386mm
Key Data HESTA180 HESTA200 mm  mm Linear mould Stroke A 180  200 Mould Width B 200  220 Mould Length  C 230 (260) 230 (260) Mould Thickness  D 2x60 - 2x75 2x60-2x75 Opening Stroke E 140  - 110 140 - 110  Platen daylight 260 260  Clamping Force 27 kN 27 kN  Dry Cycle 1,3 sec. 1,3 sec. Centre Distances  2 fold 50 /60/70 50 /60/70/85 3 fold 50 50 /60 4 fold available on request  Extruder ø 36 ø 45  Drive Hydromotor, infinitely variable Screw Speed min ¯ ¹ 0  100 0  100  Screw mm 36 / 20 D 45 / 20 D
Energy Requirements Electromotor Hydraulic / Extruder
kW 7,5 11 
Heating Capacity (Extruder)
kW 4,4 6,6
Electric Control, approx.  kW 1 1 Total Connected Load, approx.  kW 13 19 Air Requirement, approx. Nl / min 250 250 Air Working Pressure bar 7 - 10 7 - 10 Cooling Requirement Hydraulic System  kJ / h 8.000  10.000 Blow Mold  kJ / h 10.000  15.000